ver : a_0 update : 2010.09.24 led power alf100 series 100 watts electrical specifications model no. alf100-12s alf100-24s alf100-36s alf100-48s max output wattage (w) 125w 150w voltage 90-264 vac or 120-370 vdc (h type up to 277 vac) frequency (hz) 47-63 hz current (full load) 2 a max. (115 vac) / 1 a max. (230 vac) inrush current (<2ms) 30 a max. (115 vac) / 60 a max. (230 vac) leakage current <0.5 ma max. input power factor pf>0.97 (115 vac) / pf>0.93 (230 vac) at full load voltage (v.dc.) 12v 24v 36v 48v constant current range (v.dc.) 6 ~ 12v 12 ~ 24v 18 ~ 36v 24 ~ 48v voltage accuracy 2% current (convection) (a) max 8.3 4.16 2.77 2.1 current adjustment range (a) 4 ~ 8.3 2.1 ~4.16 1.4 ~ 2.77 1 ~ 2.1 line regulation 1% load regulation 1% minimum load 0% maximum capacitive load 470-23,000f depending on model ripple & noise (max.) 1% of vout max. efficiency (typ.) 90% 90% 92% 93% hold-up time 18 ms min. output switching frequency 100 khz over power protection auto recovery over voltage protection auto recovery short temperature auto recovery protection short circuit protection auto recovery input-output (v.ac) 3000v input-fg (v.ac) 1500v isolation output-fg . (v.ac) 500v operating temperature -25c?+70c (with derating) storage temperature -40c?+85c temperature coefficient 0.02%/c ( 0~50c ) humidity 95% rh mtbf >100,000 h @ 25c (mil-hdbk-217f) environment vibration 10~500hz, 5g 10min./1cycle, 60min. each along x, y, z axes. key features ? ip65 design for indoor or led outdoor installations ? universal input: 100-240 vac (up to 277 vac) ? bulit-in active pfc function, pf>0.95 ? free air convection ? high reliability ? with constant current & constant voltage ? output voltage and constant current level can be adjusted through inte rnal potential meter ? led power application ? 2-years product warranty
ver : a_0 update : 2010.09.24 led power alf100 series 100 watts model no. alf100-12s alf100-24s alf100-36s alf100-48s dimension (l x w x h) 8.35 x 2.76 x 1.50 inches (212.2 x 70.0 x 38.0 mm ) tolerance 0.5 mm weight 1010 g physical cooling method free air convection safety agency approvals design refer to ul60950-1 , ce , class i emi (conducted & radiated emission) design refer to en 61000-6-3 en 55015 emc ems (noise immunity) design refer to en 55024 (surge 4kv) mechanical dimension ( top view ) derating block diagram 1. all specifications valid at nom inal input voltage, full load and +25c after warm-up time unless otherwise stated. 2. ripple & noise are measured a t 20mhz of bandwidth with 0.1uf & 47uf parallel capacitor.
|